-
中文名称:人羧甲基赖氨酸(CML)酶联免疫试剂盒
-
货号:CSB-E12798h
-
规格:96T/48T
-
价格:¥3600/¥2500
-
其他:
产品详情
-
产品描述:
This Human CML ELISA Kit was designed for the quantitative measurement of Human CML protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 62.5 pg/mL-4000 pg/mL and the sensitivity is 15.6 pg/mL .
-
缩写:CML
-
种属:Homo sapiens (Human)
-
样本类型:serum, plasma, tissue homogenates
-
检测范围:62.5 pg/mL-4000 pg/mL
-
灵敏度:15.6 pg/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Signal Transduction
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human CML in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 87 Range % 82-95 1:2 Average % 94 Range % 90-100 1:4 Average % 95 Range % 91-105 1:8 Average % 94 Range % 85-100 -
回收率:
The recovery of human CML spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 92 85-98 EDTA plasma (n=4) 94 91-100 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. pg/ml OD1 OD2 Average Corrected 4000 2.372 2.252 2.312 2.162 2000 1.775 1.660 1.718 1.568 1000 1.160 1.142 1.151 1.001 500 0.712 0.699 0.706 0.556 250 0.493 0.456 0.475 0.325 125 0.342 0.329 0.336 0.186 62.5 0.264 0.249 0.257 0.107 0 0.153 0.147 0.150 -
数据处理:
-
货期:3-5 working days
引用文献
- Protective effect of Inonotus obliquus polysaccharide on MGO-induced nonenzymatic glycation fibroblasts C Chen,Heliyon,2024
- Serum Advanced Glycation End Products and Their Soluble Receptor as New Biomarkers in Systemic Lupus Erythematosus I Carrión,Biomedicines,2024
- Protective effect of Inonotus obliquus polysaccharide on fibroblasts after MGO-induced nonenzymatic glycation C Chen,/,2023
- Advanced Glycation end Products and Bone Metabolism in Patients With Chronic Kidney Disease KRS Quadros,JBMR Plus,2023
- The role of advanced glycation end products in vascular aging: which parameter is the most suitable as a biomarker? O Mayer,Journal of Human Hypertension,2020
- Methylglyoxal and Glyoxal as Potential Peripheral Markers for MCI Diagnosis and Their Effects on the Expression of Neurotrophic, Inflammatory and Neurodegenerative Factors in Neurons and in Neuronal Derived-Extracellular Vesicles Haddad M, et al,International Journal of Molecular Sciences,2019
- Circulating and Extracellular Vesicles Levels of N-(1-Carboxymethyl)-L-Lysine (CML) Differentiate Early to Moderate Alzheimer’s Disease Haddad M,journal of alzheimers disease,2019
- The effects of n-3 long-chain polyunsaturated fatty acid supplementation on AGEs and sRAGE in type 2 diabetes mellitus Kurt A.et al,J Physiol Biochem.,2016
- Reduction Levels and the Effects of High-Molecular-Weight Adiponectin via AMPK/eNOS in Chinese Type 2 Diabetes Lian K.et al,Exp Clin Endocrinol Diabetes.,2016
- Pomegranate (Punicagranatum) juice decreases lipid peroxidation, but has no effect on plasma advanced glycated end-products in adults with type 2 Sohrab G. et al,Food Nutr Res,2015
问答及客户评论
Does this kit measure the total or protein bound cml?
We have planned to assess the abundance of cml in protein samples, collected from cell cultures, using the human CML ELISA kit CSB-E12798h. What kind of lysis buffer is recommended to use to collect CML in cell samples? We are used to lyse cell with T-PER/Protease inhibitor cocktail or Igepal at 0.5%. Are they compatible with the purchased CML Elisa kit (CSB-E12798h)
From your description, you want to make detection on cell lysis, here advice you to use the sample method on our attached manual.
As for the method you mentioned, so sorry that it is not verified from our side.
If your sample has been prepared, pls arrange preliminary experiment to check.
The enzyme proportion should be combined with the enzyme preparation protocol.
And dear, we have 24T trial kit, if you have interest, advice you to have this small size for try.
Any question, pls feel free to contact me.Pls let me know if you have any further questions. Thank you.
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-